Başlık için Fizik Mühendisliği Bölümü Koleksiyonu listeleme
Toplam kayıt 76, listelenen: 13-32
-
Calculation of radiation shielding parameters of YBa2Cu3O7 and Y3Ba5Cu8O18 superconductors for the energies from 122 to 1332 keV using EGS4 code
(Elsevier Bv, 2023)This Study aims to evaluate the radiation shielding efficiency of YBa2Cu3O7 and Y3Ba5Cu8O18 superconducting ceramics. In the current study, the radiation shielding efficiency of YBa2Cu3O7 and Y3Ba5Cu8O18 superconducting ... -
Calculation of radiation shielding parameters of YBa2Cu3O7 and Y3Ba5Cu8O18 superconductors for the energies from 122 to 1332 keV using EGS4 code
(Elsevier B.V., 2023)This Study aims to evaluate the radiation shielding efficiency of YBa2Cu3O7 and Y3Ba5Cu8O18 superconducting ceramics. In the current study, the radiation shielding efficiency of YBa2Cu3O7 and Y3Ba5Cu8O18 superconducting ... -
Calculation of the Effects of Silver (Ag) Dopant on Radiation Shielding Efficiency of BiPbSrCaCuO Superconductor Ceramics Using EGS4 Code
(Multidisciplinary Digital Publishing Institute (MDPI), 2023)In the current study, the effects of silver (Ag) additive on the radiation shielding efficiency of BiPbSrCaCuO superconducting ceramics was calculated using the EGS4 code and discussed theoretically by comparison with XCOM ... -
Cancer risk analysis of some drinking water resources in Gumuhane, Turkey
(Springer International Publishing Ag, 2019)Water; it is the basic necessity of living things that exist in the world like air and food. An adult person consumes an average of 2 L of water per day by drinking. This consumed water contains a number of radionuclides. ... -
COMPARISON OF TWO PULSE PILE-UP CORRECTION METHODS
(TÜRK FİZİK DERNEĞİ 33.ULUSLARARASI FİZİK KONGRESİ , 2017, 2017-09-06)[Abstract Not Available] -
A Compton Suppression System For Gamma-Ray Spectroscopy
(TESNAT(3rd International Conference On Theoretical And Experimental Studies In Nuclear Applications And Technology) , 2017, 2017-05-10)[Abstract Not Available] -
Correction Of The Pulse Pile-Up Reject And The Pulse Pile-Up For Gamma Ray Spectrometry
(TESNAT( 3rd International Conference On Theoretical And Experimental Studies In Nuclear Applications And Technology) , 2017, 2017-05-10)[Abstract Not Available] -
Determination of indoor radon and soil radioactivity levels in Giresun, Turkey
(ELSEVIER SCI LTD, THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, OXON, ENGLAND, 2008-08)Indoor radon survey and gamma activity measurements in soil samples were carried out in the Giresun province (Northeastern Turkey). The result of analysis of variance showed a relationship between indoor radon and radium ... -
Determination of Natural Radioactivity Level in Some Milk Samples Consumed in Eastern Black Sea Region of Turkey
(TFD 25 Uluslararası Fizik Kongresi Bildiri Özetleri Kitabı s 203 Bodrum, 2008-08-25)[Abstract Not Available] -
Determination of Proper Peaking Time for Ultra Lege Detector at Medium Energies
(TFD 25 Uluslararası Fizik Kongresi Bildiri Özetleri Kitabı s 60 Bodrum, 2008-08-25)[Abstract Not Available] -
Determination of proper peaking time for Ultra-LEGe detector
(Pergamon-Elsevier Science Ltd, 2011)Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the proper peaking time for particular detector systems is important. The characteristic ... -
Determination Of Radioactivity Concentrations In Soil Samples And Dose Assessment For Gümüşhane Province, Turkey
(TURKISH PHYSICAL SOCIETY 34TH INTERNATIONAL PHYSICS CONGRESS , 2018, 2018-09-05)[Abstract Not Available] -
The Determination Of The Pulse Pile Up Reject Pur Counting For X And Gamma Rayspectrometry
(TÜRK FİZİK DERNEĞİ 32. ULUSLARARASI FİZİK KONGRESİ , 2016, 2016-09-06)[Abstract Not Available] -
The Determination of the Pulse Pile-up Reject (PUR) Counting for X and Gamma Ray Spectrometry
(Amer Inst Physics, 2017)The collection the charged particles produced by the incident radiation on a detector requires a time interval. If this time interval is not sufficiently short compared with the peaking time of the amplifier, a loss in the ... -
Determination of the Radon Concentration and Radioactivity Level in Karaca Cave
(TFD 25 Uluslararası Fizik Kongresi Bildiri Özetleri Kitabı s 110 Bodrum, 2008-08-25)[Abstract Not Available] -
Determinaton Of Natural 226ra 232th And 40k And Artificial 137cs Radioactivity Concentrations In Soil Samples Collected From Gümüşhane
(TÜRK FİZİK DERNEĞİ 32.ULUSLARARASI FİZİK KONGRESİ , 2016, 2016-09-06)[Abstract Not Available] -
Determinaton Of Natural And Artificial Radioactivity Concentrations In Soil Samples Collected From The Vicinity Of Kelkit-Gümüşhane
(TÜRK FİZİK DERNEĞİ 33.ULUSLARARASI FİZİK KONGRESİ-BODRUM , 2017, 2017-09-06)[Abstract Not Available] -
DTL cavity design and beam dynamics for a TAC linear proton accelerator
(Chinese Physics C, 2012-02)A 30 mA drift tube linac (DTL) accelerator has been designed using SUPERFISH code in the energy range of 3-55 MeV in the framework of the Turkish Accelerator Center (TAC) project. Optimization criteria in cavity design are ... -
The Effect Of Collimation On The Shape Of The Compton Continuum And Backscattering Peaks.
(TESNAT(3rd International Conference On Theoretical And Experimental Studies In Nuclear Applications And Technology) , 2017, 2017-05-10)[Abstract Not Available] -
Effect of detector crystal size on Compton suppression factors
(Taylor and Francis Ltd., 2023)The geometrical parameters which affect the suppression factor for an HPGe (High Purity Germanium)-NaI Compton suppression spectrometer were studied by a Monte Carlo simulation with the EGS4 system. The spectrums were ...