Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDemırağ Hatice
dc.contributor.authorKulakaç Nurşen
dc.date.accessioned2024-12-04T08:43:27Z
dc.date.available2024-12-04T08:43:27Z
dc.date.issued2024 Oct 28en_US
dc.identifier.citation1: Demırağ H, Kulakaç N. The effect of using a local skin cooling device on arteriovenous fistula cannulation pain and comfort level of patients on hemodialysis: A single-blind randomized controlled study. Hemodial Int. 2024 Oct 28. doi: 10.1111/hdi.13190. Epub ahead of print. PMID: 39467833.en_US
dc.identifier.urihttps://pubmed.ncbi.nlm.nih.gov/39467833/
dc.identifier.urihttps://hdl.handle.net/20.500.12440/6358
dc.description.abstractIntroduction: The study aimed to investigate the impact of the using local skin cooling on arteriovenous fistula cannulation pain and the comfort levels of hemodialysis patients. Methods: The single-blind randomized controlled trial was formed with 50 patients between June 20, 2023, and July 31, 2023, in the hemodialysis units of two state hospitals in Turkey. Patients were randomly assigned to either the experimental group (n = 25) or the control group (n = 25) using the block randomization method. This data were collected through the use of the CoolSense device, the "Patient Information Form," the "Verbal Category Scale," and the "General Comfort Scale." Patients in the experimental group received the local skin cooling for five seconds during arteriovenous fistula cannulation, while the control group followed the standard hospital protocol. The study was registered on Clinical Trials (NCT06144801). Findings: The study revealed that the application of the local skin cooling during arteriovenous fistula cannulation significantly reduced pain and increased patients' comfort levels, demonstrating an anesthetic effect (p < 0.001). Furthermore, it was observed that as pain levels decreased, patient comfort levels increased (p < 0.001). Discussion: It is concluded that the using lokal skin cooling is an effective tool for reducing pain and enhancing comfort during arteriovenous fistula cannulation in hemodialysis patients.en_US
dc.language.isoengen_US
dc.publisherPubMed Disclaimeren_US
dc.relation.ispartofHemodial Int .en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCoolSense; arteriovenous fistula; cannulation; hemodialysis; pain.en_US
dc.titleThe effect of using a local skin cooling device on arteriovenous fistula cannulation pain and comfort level of patients on hemodialysis: A single-blind randomized controlled studyen_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.departmentMeslek Yüksekokulları, Kelkit Sağlık Hizmetleri Meslek Yüksekokulu, Tıbbi Hizmetler ve Teknikler Bölümüen_US
dc.authorid0000-0002-2393-563Xen_US
dc.authorid0000-0002-5427-1063en_US
dc.contributor.institutionauthorDemırağ, Hatice
dc.contributor.institutionauthorKulakaç, Nurşen