Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKaya, Selim
dc.contributor.authorÇeli̇k, Necati
dc.contributor.authorBayram, Tuncay
dc.date.accessioned2023-02-02T06:36:22Z
dc.date.available2023-02-02T06:36:22Z
dc.date.issued2022en_US
dc.identifier.citationKaya, S., Çeli̇k, N., & Bayram, T. (2022). Effect of front, lateral and back dead layer thicknesses of a HPGe detector on full energy peak efficiency. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1029 doi:10.1016/j.nima.2022.166401en_US
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0168900222000626?via%3Dihub
dc.identifier.urihttps://hdl.handle.net/20.500.12440/5712
dc.description.abstractAs well known, High Purity Germanium (HPGe) detectors have a wide range of applications in every area where radiation detection and measurements are involved. One of the most important parameters in this respect is the determination of the full energy peak (FEP) efficiency. There are certain parameters affecting the so-called FEP efficiency. Perhaps the most important one is the thickness of dead layers of the crystal itself. In the current study, we investigated the effects of the thickness of front, lateral and back dead layer thicknesses of the detector crystal on the FEP efficiencies for the energy range 30 keV–5 MeV using EGS4 Monte Carlo simulation package. It was shown that the change in the thickness of the front dead layer has significant effect on the efficiency values for the energy interval 30–400 keV. The change in the thickness of the lateral and back dead layer was shown to have significant effects on the efficiencies for the energy intervals 2–3 MeV and 3–5 MeV, respectively. The results were checked using GEANT4 and a good agreement was observed.en_US
dc.language.isoengen_US
dc.publisherElsevier B.V.en_US
dc.relation.ispartofNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipmenten_US
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_US
dc.subjectHPGe detectoren_US
dc.subjectCrystal dead layeren_US
dc.subjectFEP efficiencyen_US
dc.titleEffect of front, lateral and back dead layer thicknesses of a HPGe detector on full energy peak efficiencyen_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Fizik Mühendisliği Bölümüen_US
dc.authorid0000-0001-7477-3522en_US
dc.authorid0000-0002-8270-9288en_US
dc.identifier.volume1029en_US
dc.identifier.issue166401en_US
dc.contributor.institutionauthorKaya, Selim
dc.contributor.institutionauthorÇeli̇k, Necati
dc.identifier.doi10.1016/j.nima.2022en_US
dc.authorwosidGZK-8395-2022en_US
dc.authorwosidZ-5784-2019en_US
dc.authorscopusid23979457000en_US
dc.authorscopusid18634155200en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster