Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorMenevseoglu, Ahmed
dc.date.accessioned2021-11-09T19:55:03Z
dc.date.available2021-11-09T19:55:03Z
dc.date.issued2021
dc.identifier.issn2149-0120
dc.identifier.issn2149-0120
dc.identifier.urihttps://doi.org/10.18596/jotcsa.940424
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TkRVeE1EYzBOQT09
dc.identifier.urihttps://hdl.handle.net/20.500.12440/4268
dc.description.abstractEdible oils are often adulterated with fixed oils because of their high quality and price. Sesame oil is prone to adulteration due to its high commodity value and popularity. Therefore, a rapid, simple, and non-invasive method to detect adulteration in sesame oil is necessary for quality control purposes. Handheld and portable FT-NIR, FT-MIR, and Raman spectrometers are easy to operate, non-destructive, rapid, and easy to transport for in-situ assessments as well as being cheaper alternatives to traditional instruments. This study aimed to evaluate three different vibrational spectroscopic techniques in detecting sesame oil adulteration with sunflower and canola oil. Sesame oils were adulterated with fixed oils at different concentrations (0 – 25%) (w/w). Spectra were collected with portable devices and analyzed using Soft Independent Modelling of Class Analogy (SIMCA) to generate a classification model to authenticate pure sesame oil and Partial Least Squares Regression (PLSR) to predict the levels of the adulterant. For confirmation, the fatty acid profile of the oils was determined by gas chromatography (GC). In all three instruments, SIMCA provided distinct clusters for pure sesame oils and adulterated samples with interclass distance (ICD) over 3. Furthermore, FT-NIR and FT-MIR showed excellent performance in predicting adulterant levels with rval>0.96. Specifically, the FT-MIR unit provided more precise classification and PLSR prediction models over FT-NIR and Raman units. Still, all the units can be used as an alternative method to traditional methods such as GC, GC-MS, etc. These units showed great potential for in-situ surveillance to detect sesame oil adulterations.en_US
dc.description.abstracten_US
dc.language.isoengen_US
dc.relation.ispartofJournal of the Turkish Chemical Society, Section A: Chemistryen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject[No Keywords]en_US
dc.titleNon-destructive Detection of Sesame Oil Adulteration by Portable FTNIR, FT-MIR, and Raman Spectrometers Combined with Chemometricsen_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.description.scopuspublicationid2-s2.0-85114010120en_US
dc.departmentGümüşhane Üniversitesien_US
dc.identifier.volume8en_US
dc.identifier.issue3en_US
dc.identifier.startpage775en_US
dc.contributor.institutionauthorMenevseoglu, Ahmed
dc.identifier.doi10.18596/jotcsa.940424
dc.identifier.endpage786en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster