dc.contributor.authorAltunisik, Ahmet Can
dc.contributor.authorGunaydin, Murat
dc.contributor.authorSevim, Baris
dc.contributor.authorBayraktar, Alemdar
dc.contributor.authorAdanur, Suleyman
dc.date.accessioned2021-11-09T19:49:16Z
dc.date.available2021-11-09T19:49:16Z
dc.date.issued2016
dc.identifier.issn0887-3828
dc.identifier.issn1943-5509
dc.identifier.urihttps://doi.org/10.1061/(ASCE)CF.1943-5509.0000890
dc.identifier.urihttps://hdl.handle.net/20.500.12440/3993
dc.description.abstractThis technical note presents an investigation about the changing of dynamic characteristics of an arch dam model before and after strengthening considering reservoir water. To this end, an arch dam-reservoir-foundation model has been constructed in the laboratory. Ambient vibration tests have been performed on the damaged and strengthened arch dam models for empty and full reservoir to determine the effect of water on the dynamics characteristics. Enhanced frequency domain decomposition method has been used to extract the dynamic characteristics. Finally, the dynamic characteristics obtained from the damaged and strengthened dam models have been compared to with each other. Also, the natural frequencies for damaged and strengthened models are compared to detect the effect of strengthening application on the frequencies. Results indicate that the natural frequencies and damping ratios are changed with the full reservoir. However, mode shapes are not changed. Results also show that the natural frequencies of damaged dam considerably increase after strengthening applications.en_US
dc.description.sponsorshipTUBITAKTurkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK); Karadeniz Technical UniversityKaradeniz Technical University [106M038, 2005.112.001.1]en_US
dc.description.sponsorshipTUBITAK and Karadeniz Technical University supported this research under Research Grant No. 106M038 and 2005.112.001.1, respectively; that support is greatly appreciated. The authors also thank BASF Company, Turker Sinici, and Ali Kose for their collaboration.en_US
dc.language.isoengen_US
dc.publisherAsce-Amer Soc Civil Engineersen_US
dc.relation.ispartofJournal of Performance of Constructed Facilitiesen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAmbient vibration testen_US
dc.subjectArch damen_US
dc.subjectDynamic characteristicsen_US
dc.subjectStrengtheningen_US
dc.titleDynamic Characteristics of an Arch Dam Model before and after Strengthening with Consideration of Reservoir Wateren_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.description.wospublicationidWOS:000388619000006en_US
dc.description.scopuspublicationid2-s2.0-84996917829en_US
dc.departmentGümüşhane Üniversitesien_US
dc.authoridProfessor Alemdar BAYRAKTAR, BSc / 0000-0002-8973-9228
dc.authoridALTUNISIK, Ahmet Can / 0000-0002-2638-2903
dc.authoridSEVIM, Baris / 0000-0003-3828-3571
dc.authoridgunaydin, murat / 0000-0002-8549-2985
dc.identifier.volume30en_US
dc.identifier.issue6en_US
dc.identifier.doi10.1061/(ASCE)CF.1943-5509.0000890
dc.authorwosidAdanur, Suleyman / AAT-3469-2020
dc.authorwosidProfessor Alemdar BAYRAKTAR, BSc / M-5881-2017
dc.authorwosidALTUNISIK, Ahmet Can / AAI-1675-2019
dc.authorwosidSEVIM, Baris / R-2256-2019
dc.authorwosidgunaydin, murat / AAT-1687-2020
dc.authorscopusid23395831800
dc.authorscopusid57197604677
dc.authorscopusid26428442300
dc.authorscopusid6602269704
dc.authorscopusid12242101900