dc.description.abstractMass attenuation coefficients were determined experimentally for Sc, Ni and W for gamma energies of 59.5, 122, 276, 302, 356, 383 and 662 keV for different detector collimator diameters ranging from 2 to 10 mm. The aim was to investigate the quantitative analysis of detector collimator diameter effect on measured mass attenuation coefficients. It was found that measured mass attenuation coefficients decrease systematically with the increasing collimator diameter. The relative difference was found to be up to around 3% in some cases. The observed decrease in mass attenuation coefficients was attributed to the detection of elastic and inelastic scattered photons from the absorber. In elastic scattering process the photons change in direction but not in energy and get counted under the full energy peak if they reach the detector. In inelastic scattering however, both direction and energy of the scattered photons change. It was seen that most of the inelastic scattered photons also get counted by the detection system since they lose an amount of energy lower than the energy resolution of the detector. It is understood from the present results that it is essential to take into account the experimental geometry when reporting mass attenuation coefficients. (C) 2012 Elsevier B.V. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.ispartofNuclear Instruments & Methods in Physics Research Section B-Beam Interactions With Materials and Atomsen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMass attenuation coefficienten_US
dc.subjectScen_US
dc.subjectNien_US
dc.subjectWen_US
dc.subjectDetector collimationen_US
dc.subjectTransmission methoden_US
dc.titleEffect of detector collimation on the measured mass attenuation coefficients of some elements for 59.5-661.6 keV gamma-raysen_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.description.wospublicationidWOS:000304895000002en_US
dc.description.scopuspublicationid2-s2.0-84861120226en_US
dc.departmentGümüşhane Üniversitesien_US
dc.authoridCELIK, AHMET / 0000-0002-9618-3504
dc.identifier.volume281en_US
dc.identifier.startpage8en_US
dc.identifier.doi10.1016/j.nimb.2012.04.003
dc.identifier.endpage14en_US
dc.authorwosidCevik, U. / AAW-2997-2020
dc.authorscopusid23979457000
dc.authorscopusid8599845000
dc.authorscopusid57196590493


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster