Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorCelik, Necati
dc.contributor.authorAltin, Duygu
dc.contributor.authorCevik, Ugur
dc.date.accessioned2021-11-09T19:48:46Z
dc.date.available2021-11-09T19:48:46Z
dc.date.issued2015
dc.identifier.issn0969-806X
dc.identifier.urihttps://doi.org/10.1016/j.radphyschem.2015.07.002
dc.identifier.urihttps://hdl.handle.net/20.500.12440/3791
dc.description.abstractIn the presented study, a code was created for the purpose of true coincidence summing (TCS) correction factors for Cs-134. The created code was implemented in EGS4 Monte Carlo simulation package. TCS factors were determined for nine different energies for different detector-source geometries. The calculated results were successfully validated by an empirical method using a point Cs-134 radioactive source and a p-type HPGe detector having 55% relative efficiency. Although the code created gives TCS factors only for Cs-134 the technique presented can be used to obtain the factors for any radionuclide used in gamma-ray spectrometry. (C) 2015 Elsevier Ltd. All rights reserved.en_US
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK)en_US
dc.description.sponsorshipThis work was carried out during the training period at Institute for Reference Materials and Measurements (IRMM) supported by The Scientific and Technological Research Council of Turkey (TUBITAK). The author would like to thank Marie-Martine Be from French Alternative Energies and Atomic Energy Commission Laboratorie national Henri Becquerel for providing Nucleide 2000 (version 3) software.en_US
dc.language.isoengen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.relation.ispartofRadiation Physics and Chemistryen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMonte Carloen_US
dc.subjectEGS4en_US
dc.subjectTrue coincidence summing correctionen_US
dc.subjectCs-134en_US
dc.titleBuilding-up a code for the purpose of TRUE coincidence summing correction in gamma-ray spectrometry with EGS4en_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.description.wospublicationidWOS:000359885700025en_US
dc.description.scopuspublicationid2-s2.0-84936949469en_US
dc.departmentGümüşhane Üniversitesien_US
dc.identifier.volume115en_US
dc.identifier.startpage158en_US
dc.identifier.doi10.1016/j.radphyschem.2015.07.002
dc.identifier.endpage163en_US
dc.authorwosidCevik, U. / AAW-2997-2020
dc.authorscopusid23979457000
dc.authorscopusid23566568600
dc.authorscopusid8599845000


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster