dc.contributor.author | Celik, Necati | |
dc.contributor.author | Altin, Duygu | |
dc.contributor.author | Cevik, Ugur | |
dc.date.accessioned | 2021-11-09T19:48:46Z | |
dc.date.available | 2021-11-09T19:48:46Z | |
dc.date.issued | 2015 | |
dc.identifier.issn | 0969-806X | |
dc.identifier.uri | https://doi.org/10.1016/j.radphyschem.2015.07.002 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12440/3791 | |
dc.description.abstract | In the presented study, a code was created for the purpose of true coincidence summing (TCS) correction factors for Cs-134. The created code was implemented in EGS4 Monte Carlo simulation package. TCS factors were determined for nine different energies for different detector-source geometries. The calculated results were successfully validated by an empirical method using a point Cs-134 radioactive source and a p-type HPGe detector having 55% relative efficiency. Although the code created gives TCS factors only for Cs-134 the technique presented can be used to obtain the factors for any radionuclide used in gamma-ray spectrometry. (C) 2015 Elsevier Ltd. All rights reserved. | en_US |
dc.description.sponsorship | Scientific and Technological Research Council of Turkey (TUBITAK)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) | en_US |
dc.description.sponsorship | This work was carried out during the training period at Institute for Reference Materials and Measurements (IRMM) supported by The Scientific and Technological Research Council of Turkey (TUBITAK). The author would like to thank Marie-Martine Be from French Alternative Energies and Atomic Energy Commission Laboratorie national Henri Becquerel for providing Nucleide 2000 (version 3) software. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Pergamon-Elsevier Science Ltd | en_US |
dc.relation.ispartof | Radiation Physics and Chemistry | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Monte Carlo | en_US |
dc.subject | EGS4 | en_US |
dc.subject | True coincidence summing correction | en_US |
dc.subject | Cs-134 | en_US |
dc.title | Building-up a code for the purpose of TRUE coincidence summing correction in gamma-ray spectrometry with EGS4 | en_US |
dc.type | article | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.description.wospublicationid | WOS:000359885700025 | en_US |
dc.description.scopuspublicationid | 2-s2.0-84936949469 | en_US |
dc.department | Gümüşhane Üniversitesi | en_US |
dc.identifier.volume | 115 | en_US |
dc.identifier.startpage | 158 | en_US |
dc.identifier.doi | 10.1016/j.radphyschem.2015.07.002 | |
dc.identifier.endpage | 163 | en_US |
dc.authorwosid | Cevik, U. / AAW-2997-2020 | |
dc.authorscopusid | 23979457000 | |
dc.authorscopusid | 23566568600 | |
dc.authorscopusid | 8599845000 | |