The effect of TiO2 coating on biological NiTi alloys after micro-arc oxidation treatment for corrosion resistance
Erişim
info:eu-repo/semantics/closedAccessTarih
2017Yazar
Sukuroglu, Ebru EmineSukuroglu, Suleyman
Akar, Kubra
Totik, Yasar
Efeoglu, Ihsan
Arslan, Ersin
Erişim
info:eu-repo/semantics/closedAccessÜst veri
Tüm öğe kaydını gösterÖzet
NiTi alloys exhibit good properties, such as shape memory behavior, high corrosion resistant, having the closest elasticity modulus of a human bone and superior biocompatibility properties. However, the surface problems that arise during the use of this alloy limit the usage in the industry and health sector. In recent years, micro-arc oxidation method is used to improve the surface properties and increase the usage of these alloys. In this study, the TiO2 coatings were deposited on the NiTi substrates. The surface topography, morphology, crystallographic structure, and thickness of the coatings were determined using scanning electron microscopy and X-ray diffraction. The corrosion properties were investigated using potentiostat test unit in two different media such as NaCl solution and simulated body fluid. The results show that the coated samples have higher corrosion resistance than uncoated samples in the two different media.