dc.contributor.author | Ozden, Talat | |
dc.contributor.author | Yardim, Ugur | |
dc.contributor.author | Akinoglu, Bulent G. | |
dc.contributor.author | Turan, Rasit | |
dc.date.accessioned | 2021-11-09T19:43:06Z | |
dc.date.available | 2021-11-09T19:43:06Z | |
dc.date.issued | 2015 | |
dc.identifier.issn | 1862-6351 | |
dc.identifier.uri | https://doi.org/10.1002/pssc.201510077 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12440/3550 | |
dc.description | 3rd Turkish Solar Electricity Conference and Exhibition (SolarTR) -- APR 27-29, 2015 -- Ankara, TURKEY | en_US |
dc.description.abstract | The present paper is mainly a comparison of the performances of two PV systems under outdoor conditions in Ankara. The systems are grid connected and consist of two PV arrays. The types of these PV arrays are CdTe thin film and amorphous silicon/micro-crystalline-based (mu c-Si/a-Si) arrays. They are operated for 3 years; 2012-2014. Yearly averages of monthly efficiencies of these two systems working under the same ambient conditions are 6.88%, 6.65%, 6.80% and 6.64%, 5.86%, 5.25% for mu c-Si/a-Si and CdTe, respectively. Using these values, simple calculation results for the degradation rates per year are about 0.39%/year and 6.98%/year, respectively for these two types of systems. (C) 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim | en_US |
dc.description.sponsorship | Aselsan A S, Turkiye Sise Cam Fabrikalari A S, Halk Enerji Yatirimlari Uretim Ins Taahhut Tic San A S, Dorutek Teknoloji Ltd Sti, Seiso Enerji Sis Muh San Tic A S, GTC Dis Ticaret Ltd Sti, Air Liquide | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Wiley-V C H Verlag Gmbh | en_US |
dc.relation.ispartof | Physica Status Solidi C: Current Topics in Solid State Physics, Vol 12, No 9-11 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | amorphous silicon | en_US |
dc.subject | CdTe | en_US |
dc.subject | PV efficiency | en_US |
dc.subject | PV degradation | en_US |
dc.subject | PV outdoor test | en_US |
dc.title | Outdoor efficiency analyses and comparison of on-grid CdTe and mu c-Si/a-Si thin-film PV systems for three years in Ankara - Turkey | en_US |
dc.type | conferenceObject | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.description.wospublicationid | WOS:000372057300019 | en_US |
dc.description.scopuspublicationid | 2-s2.0-84955719903 | en_US |
dc.department | Gümüşhane Üniversitesi | en_US |
dc.identifier.volume | 12 | en_US |
dc.identifier.issue | 9-11 | en_US |
dc.identifier.startpage | 1283 | en_US |
dc.identifier.doi | 10.1002/pssc.201510077 | |
dc.identifier.endpage | 1287 | en_US |
dc.authorwosid | Turan, Rasit / ABB-4627-2020 | |
dc.authorwosid | OZDEN, Talat / ABH-1750-2020 | |
dc.authorscopusid | 36976213500 | |
dc.authorscopusid | 56928398400 | |
dc.authorscopusid | 6602089703 | |
dc.authorscopusid | 8307543400 | |