Determination of the dependence of HPGe virtual point detector location on source dimensions in 60 keV-2MeV range using Monte Carlo simulation
Erişim
info:eu-repo/semantics/closedAccessTarih
2012Erişim
info:eu-repo/semantics/closedAccessÜst veri
Tüm öğe kaydını gösterÖzet
The virtual point detector (VPD) concept for an HPGe detector with 55% relative efficiency was confirmed for bulky sources having different diameters and heights. After reproducing experimental data, Monte Carlo simulation was used to investigate the dependence of VPD location on photon energy for various source diameters and heights in the energy range from 60 keV to 2MeV. The simulations were confirmed using a soil reference source prepared by International Atomic Energy Agency (IAEA). It was seen that increasing photon energy makes significant changes in VPD location up to 600 keV. It was observed that VPD locations increase with increasing source diameter and height. It was also seen that VPD locations were approximately linearly dependent on source diameters and heights.