Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorGezen, Cem
dc.contributor.authorKement, Metin
dc.contributor.authorAltuntas, Yunus E.
dc.contributor.authorAksakal, Nihat
dc.contributor.authorOkkabaz, Nuri
dc.contributor.authorCivil, Osman
dc.contributor.authorOncel, Mustafa
dc.date.accessioned2021-11-09T19:41:44Z
dc.date.available2021-11-09T19:41:44Z
dc.date.issued2012
dc.identifier.issn1092-6429
dc.identifier.issn1557-9034
dc.identifier.urihttps://doi.org/10.1089/lap.2012.0083
dc.identifier.urihttps://hdl.handle.net/20.500.12440/3040
dc.description.abstractBackground: LigaSure (TM) (Covidien, Mansfield, MA) has been used in cases undergoing laparoscopic colon and rectal resections. This study aims to analyze the efficacy and safety of the 5-mm and 10-mm devices. Subjects and Methods: Patients who received a laparoscopic or hand-assisted laparoscopic operation for a tumor located in the sigmoid colon or rectum since 2006 were abstracted from a prospectively designed database, and findings were analyzed in two groups based on size of the device used during the procedure. The videotapes of the procedures were watched, and operation reports were read to obtain further information on specific intra- and postoperative complications. Demographics, tumor and operation-related information, and postoperative data were compared. Results: Among 215 (128 [59.5%] males; median age, 59.5 +/- 13.8 years) patients, data obtained from the 5-mm (n = 32) and 10-mm (n = 183) groups were identical regarding demographics and data related to tumor (localization and stage) and operation (number of harvested lymph nodes, conversion rates, operation time, intraoperative bleeding, transfusion requirement, reoperation rates, complications, 30-day mortality, and length of hospital stay). However, more patients underwent an anterior resection in the 10-mm group than in the 5-mm group (31.7% versus 15.6%, P < .05). Further analyses found device-related bleeding in 8 (3.7%) cases (2 [6.3%] versus 6 [3.3%] in the 5-mm versus 10-mm group, respectively, P > .05), requiring further attempts for hemorrhage control (n = 6), conversion to open surgery (n = 1), or relaparotomy (n = 1). Conclusions: The 5-mm and 10-mm LigaSure devices are similarly effective and safe during laparoscopic sigmoid colon and rectal resections. Severe bleeding from larger vessels may be observed, requiring conversion to open surgery or relaparotomy.en_US
dc.language.isoengen_US
dc.publisherMary Ann Liebert, Incen_US
dc.relation.ispartofJournal of Laparoendoscopic & Advanced Surgical Techniquesen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectUltrasonic Coagulating Shearsen_US
dc.subjectSurgeryen_US
dc.subjectHemostasisen_US
dc.subjectTrialen_US
dc.subjectOutcomesen_US
dc.subjectDeviceen_US
dc.titleSafety and Effectiveness of 5-mm and 10-mm Electrothermal Bipolar Vessel Sealers (LigaSure) in Laparoscopic Resections for Sigmoid Colon and Rectal Cancersen_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.description.wospublicationidWOS:000306594400010en_US
dc.description.scopuspublicationid2-s2.0-84864196743en_US
dc.departmentGümüşhane Üniversitesien_US
dc.identifier.volume22en_US
dc.identifier.issue6en_US
dc.identifier.startpage572en_US
dc.identifier.doi10.1089/lap.2012.0083
dc.identifier.endpage577en_US
dc.authorwosidOkkabaz, Nuri / U-4054-2019
dc.authorwosidOncel, Mustafa / AAP-3650-2020
dc.authorwosidAksakal, Nihat / ABB-5338-2020
dc.authorwosidCivil, Osman / AAP-7411-2020
dc.authorscopusid15042141900
dc.authorscopusid23091117100
dc.authorscopusid6701650512
dc.authorscopusid15047587100
dc.authorscopusid35102954000
dc.authorscopusid55217685100
dc.authorscopusid6603956441
dc.description.pubmedpublicationidPubMed: 22458835en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster