Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorOzturk, Ali
dc.contributor.authorDuzgun, Ibrahim
dc.contributor.authorCelebi, Selahattin
dc.date.accessioned2021-11-09T19:41:44Z
dc.date.available2021-11-09T19:41:44Z
dc.date.issued2017
dc.identifier.issn1286-0042
dc.identifier.issn1286-0050
dc.identifier.urihttps://doi.org/10.1051/epjap/2017170266
dc.identifier.urihttps://hdl.handle.net/20.500.12440/3038
dc.description.abstractMeasurements of the ac susceptibility in a commercial Bi:2223/Ag tape for some different ac magnetic field amplitudes, H-ac, in the presence of bias magnetic field H-dc directed along H-ac are reported. It is found that the peak values of the imaginary component of ac susceptibility x(max) versus H-ac trace a valley for the orientation where applied field H-a perpendicular to wide face of the tape total. We note that the observation of the valley depends on various parameters such as field dependence parameter n in the critical current density, in the simple power law expression j(c)- alpha(T)/B-n, choice of the bias field H-dc together with selected ac field amplitudes H-ac, and dimension and geometry of sample studied. Our calculations based on critical state model with j(c) - alpha(1 - T/T-cm)(p)/B-n using the fitting parameters of n - 0.25, p- 2.2, T-cm- 108 K gives quite good results to compare the experimental and calculated curves.en_US
dc.description.sponsorshipTUBITAK-TBAGTurkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [107T015]en_US
dc.description.sponsorshipTUBITAK-TBAG is gratefully knowledge for supporting the current study under grant contract no. 107T015.en_US
dc.language.isoengen_US
dc.publisherEdp Sciences S Aen_US
dc.relation.ispartofEuropean Physical Journal-Applied Physicsen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectIi Superconductorsen_US
dc.subjectMagnetic-Fieldsen_US
dc.subjectMultifilamentary Tapesen_US
dc.subjectBscco/Ag Tapesen_US
dc.subjectParallel Acen_US
dc.subjectLoss Valleyen_US
dc.subjectSusceptibilityen_US
dc.subjectDependenceen_US
dc.subjectMinimumen_US
dc.subjectFluxen_US
dc.titleEffect of dc field on ac-loss peak in a commercial Bi:2223/Ag tapeen_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.description.wospublicationidWOS:000416953700001en_US
dc.description.scopuspublicationid2-s2.0-85037541517en_US
dc.departmentGümüşhane Üniversitesien_US
dc.authorid0000-0002-7319-2619
dc.identifier.volume80en_US
dc.identifier.issue3en_US
dc.identifier.doi10.1051/epjap/2017170266
dc.authorwosidA-5301-2009
dc.authorwosidOZTURK, Ali / AAT-4604-2020
dc.authorwosidDUZGUN, IBRAHIM / W-1715-2017
dc.authorwosidAAY-7985-2020
dc.authorwosidAAX-1617-2020
dc.authorscopusid35969715300
dc.authorscopusid18037367000
dc.authorscopusid7006095287


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster