dc.contributor.author | Ozturk, Ali | |
dc.contributor.author | Duzgun, Ibrahim | |
dc.contributor.author | Celebi, Selahattin | |
dc.date.accessioned | 2021-11-09T19:41:44Z | |
dc.date.available | 2021-11-09T19:41:44Z | |
dc.date.issued | 2017 | |
dc.identifier.issn | 1286-0042 | |
dc.identifier.issn | 1286-0050 | |
dc.identifier.uri | https://doi.org/10.1051/epjap/2017170266 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12440/3038 | |
dc.description.abstract | Measurements of the ac susceptibility in a commercial Bi:2223/Ag tape for some different ac magnetic field amplitudes, H-ac, in the presence of bias magnetic field H-dc directed along H-ac are reported. It is found that the peak values of the imaginary component of ac susceptibility x(max) versus H-ac trace a valley for the orientation where applied field H-a perpendicular to wide face of the tape total. We note that the observation of the valley depends on various parameters such as field dependence parameter n in the critical current density, in the simple power law expression j(c)- alpha(T)/B-n, choice of the bias field H-dc together with selected ac field amplitudes H-ac, and dimension and geometry of sample studied. Our calculations based on critical state model with j(c) - alpha(1 - T/T-cm)(p)/B-n using the fitting parameters of n - 0.25, p- 2.2, T-cm- 108 K gives quite good results to compare the experimental and calculated curves. | en_US |
dc.description.sponsorship | TUBITAK-TBAGTurkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [107T015] | en_US |
dc.description.sponsorship | TUBITAK-TBAG is gratefully knowledge for supporting the current study under grant contract no. 107T015. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Edp Sciences S A | en_US |
dc.relation.ispartof | European Physical Journal-Applied Physics | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Ii Superconductors | en_US |
dc.subject | Magnetic-Fields | en_US |
dc.subject | Multifilamentary Tapes | en_US |
dc.subject | Bscco/Ag Tapes | en_US |
dc.subject | Parallel Ac | en_US |
dc.subject | Loss Valley | en_US |
dc.subject | Susceptibility | en_US |
dc.subject | Dependence | en_US |
dc.subject | Minimum | en_US |
dc.subject | Flux | en_US |
dc.title | Effect of dc field on ac-loss peak in a commercial Bi:2223/Ag tape | en_US |
dc.type | article | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.description.wospublicationid | WOS:000416953700001 | en_US |
dc.description.scopuspublicationid | 2-s2.0-85037541517 | en_US |
dc.department | Gümüşhane Üniversitesi | en_US |
dc.authorid | 0000-0002-7319-2619 | |
dc.identifier.volume | 80 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.doi | 10.1051/epjap/2017170266 | |
dc.authorwosid | A-5301-2009 | |
dc.authorwosid | OZTURK, Ali / AAT-4604-2020 | |
dc.authorwosid | DUZGUN, IBRAHIM / W-1715-2017 | |
dc.authorwosid | AAY-7985-2020 | |
dc.authorwosid | AAX-1617-2020 | |
dc.authorscopusid | 35969715300 | |
dc.authorscopusid | 18037367000 | |
dc.authorscopusid | 7006095287 | |