Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÇelebi, Selahattin
dc.contributor.authorDüzgün, İbrahim
dc.contributor.authorÖztürk, Ali
dc.date.accessioned2014-09-11T14:50:44Z
dc.date.available2014-09-11T14:50:44Z
dc.date.issued2009-12-23
dc.identifier.citation3en_US
dc.identifier.issn0953-2048
dc.identifier.urihttps://hdl.handle.net/20.500.12440/221
dc.description.abstractThe effect of temperature, field amplitude, frequency and orientation of the field on AC losses in a commercial Bi:2223/Ag tape prepared by the continuous filling and forming (CTFF) method has been investigated. The measurements were performed using an AC susceptometer. The experimental results show that the losses depend on field amplitude, temperature, DC field, orientation of the sample and strongly on frequency. Due to the strong dependence of AC losses on frequency, measurements were pursued at several frequencies between 20 Hz and 10 kHz at various temperatures (10, 20, 30 and 77 K). The strong frequency dependence at these low temperatures is attributed to eddy current losses and/or inter-filamentary coupling losses. At higher temperatures and low frequencies, the main contribution to AC losses comes from hysteresis losses due to the flux entry into and exit from the superconducting tape during the up and down swings of the magnetic field. We have calculated coupling losses as a function of frequency and temperature-dependent time constant. Experimental data are analyzed by comparing them with the calculated curves. From the DC field dependence of the AC susceptibility, we obtained the irreversibility line.en_US
dc.description.sponsorshipThis work was supported by TUBITAK-TBAG under grant contract no. 107T015 and Research Fund of Karadeniz Technical University under grant contract no. 2006.111.001.1.en_US
dc.language.isoengen_US
dc.publisherIOP PUBLISHING LTD, DIRAC HOUSE, TEMPLE BACK, BRISTOL BS1 6BE, ENGLANDen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMULTIFILAMENTARY TAPESen_US
dc.subjectIRREVERSIBILITY LINEen_US
dc.subjectBSCCO/AG TAPESen_US
dc.subjectFREQUENCY-DEPENDENCEen_US
dc.subjectMAGNETIC-FIELDSen_US
dc.subjectHYSTERESIS LOSSen_US
dc.subjectPOWER DEVICESen_US
dc.subjectSUPERCONDUCTORSen_US
dc.subjectCONDUCTORSen_US
dc.subjectTRANSPORTen_US
dc.titleAC loss study by AC susceptibility measurement in a commercial Bi:2223/Ag tape prepared by the CTFF method: H // c axis and short specimenen_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Fizik Mühendisliği Bölümüen_US
dc.contributor.institutionauthorÇelebi, Selahattin


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster