Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÇelebi, Selahattin
dc.contributor.authorDüzgün, İbrahim
dc.date.accessioned2014-09-11T14:41:12Z
dc.date.available2014-09-11T14:41:12Z
dc.date.issued2009-02-17
dc.identifier.citation4en_US
dc.identifier.issn0953-2048
dc.identifier.urihttps://hdl.handle.net/20.500.12440/216
dc.identifier.urihttps://iopscience.iop.org/article/10.1088/0953-2048/22/3/034018
dc.description.abstractWe have investigated the effect of temperature, field amplitude, frequency and orientation of the field on AC losses in a commercial Bi:2223/Ag tape. The measurements were performed using an AC susceptometer. The experimental results show that the losses depend on field amplitude, temperature, and strongly on frequency. Due to the strong dependence of AC losses on frequency, measurements were pursued at several frequencies between 20 Hz and 10 kHz, at both 20 and 30 K. The strong frequency dependence at these low temperatures is attributed to eddy current losses or/and inter-filamentary coupling losses. At higher temperatures and low frequencies, the main contribution to AC losses comes from hysteresis losses due to the flux entry into and exit from the superconducting tape during the up and down swings of the magnetic field. We have calculated the hysteresis losses in the critical state framework, as a function of AC field amplitudes and temperature, for planar geometry. Experimental data are analyzed by comparing them with the calculated curves.en_US
dc.description.sponsorshipThis work was supported by TUBITAK-TBAG under the grant contract number: 107T015 and Research Fund of Karadeniz Technical University.en_US
dc.language.isoengen_US
dc.publisherIOP PUBLISHING LTD, DIRAC HOUSE, TEMPLE BACK, BRISTOL BS1 6BE, ENGLANDen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBSCCO MULTIFILAMENTARY TAPESen_US
dc.subjectHIGH-TC SUPERCONDUCTORSen_US
dc.subjectSUSCEPTIBILITY MEASUREMENTSen_US
dc.subjectFREQUENCY-DEPENDENCEen_US
dc.subjectMAGNETIC-FIELDSen_US
dc.subjectHYSTERESIS LOSSen_US
dc.subjectPOWER DEVICESen_US
dc.subjectCONDUCTORSen_US
dc.subjectBEHAVIORen_US
dc.subjectCABLESen_US
dc.titleAC losses in commercial Bi:2223/Ag tapeen_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Fizik Mühendisliği Bölümüen_US
dc.contributor.institutionauthorÇelebi, Selahattin


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster