Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKarabidak, S. M.
dc.contributor.authorKaya, S.
dc.date.accessioned2019-12-10T11:43:16Z
dc.date.available2019-12-10T11:43:16Z
dc.date.issued2017
dc.identifier.citationDOI:10.1063/1.4976408 :Alan endeksleri (The Conference Proceedings Citation Index (part of Web of Science)Scopus (Elsevier)InspecChemical Abstracts Service (CAS)Astrophysics Data System (ADS))en_US
dc.identifier.isbn978-0-7354-1483-9
dc.identifier.issn0094-243X
dc.identifier.urihttps://doi.org/10.1063/1.4976408
dc.description32nd International Physics Congress of Turkish-Physical-Society (TPS) -- SEP 06-09, 2016 -- Bodrum, TURKEYen_US
dc.description.abstractThe collection the charged particles produced by the incident radiation on a detector requires a time interval. If this time interval is not sufficiently short compared with the peaking time of the amplifier, a loss in the recovered signal amplitude occurs. Another major constraint on the throughput of modem x or gamma-ray spectrometers is the time required for the subsequent the pulse processing by the electronics. Two above-mentioned limitations are cause of counting losses resulting from the dead nine and the pile-up. The pulse pile-up is a common problem in x and gamma ray radiation detection systems. The pulses pile-up in spectroscopic analysis can cause significant errors. Therefore, inhibition of these pulses is a vital step. A way to reduce en-ors due to the pulse pile-up is a pile-up inspection circuitry (PUR). Such a circuit rejects some of the pulse pile-up. Therefore, this circuit leads to counting losses. Determination of these counting losses is an important problem. In this work, a new method is suggested for the determination of the pulse pile-up reject.en_US
dc.description.sponsorshipTurkish Phys Socen_US
dc.language.isoengen_US
dc.publisherAmer Inst Physicsen_US
dc.relation.ispartofProceedings of The Turkish Physical Society 32nd International Physics Congress (Tps32)en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject[No Keywords]en_US
dc.titleThe Determination of the Pulse Pile-up Reject (PUR) Counting for X and Gamma Ray Spectrometryen_US
dc.typeconferenceObjecten_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.description.wospublicationidWOS:000435205100064en_US
dc.description.scopuspublicationid2-s2.0-85015990102en_US
dc.departmentGümüşhane Üniversitesien_US
dc.authoridKARABIDAK, Salih Mustafa / 0000-0002-3096-2476
dc.authoridKAYA, SELIM / 0000-0001-7477-3522
dc.identifier.volume1815en_US
dc.identifier.doi10.1063/1.4976408
dc.authorwosidKARABIDAK, Salih Mustafa / K-4000-2019
dc.authorwosidKAYA, SELIM / Z-5784-2019
dc.authorscopusid18634364300
dc.authorscopusid18634155200


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster