dc.contributor.author | Karabidak, S. M. | |
dc.contributor.author | Kaya, S. | |
dc.date.accessioned | 2019-12-10T11:43:16Z | |
dc.date.available | 2019-12-10T11:43:16Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | DOI:10.1063/1.4976408 :Alan endeksleri (The Conference Proceedings Citation Index (part of Web of Science)Scopus (Elsevier)InspecChemical Abstracts Service (CAS)Astrophysics Data System (ADS)) | en_US |
dc.identifier.isbn | 978-0-7354-1483-9 | |
dc.identifier.issn | 0094-243X | |
dc.identifier.uri | https://doi.org/10.1063/1.4976408 | |
dc.description | 32nd International Physics Congress of Turkish-Physical-Society (TPS) -- SEP 06-09, 2016 -- Bodrum, TURKEY | en_US |
dc.description.abstract | The collection the charged particles produced by the incident radiation on a detector requires a time interval. If this time interval is not sufficiently short compared with the peaking time of the amplifier, a loss in the recovered signal amplitude occurs. Another major constraint on the throughput of modem x or gamma-ray spectrometers is the time required for the subsequent the pulse processing by the electronics. Two above-mentioned limitations are cause of counting losses resulting from the dead nine and the pile-up. The pulse pile-up is a common problem in x and gamma ray radiation detection systems. The pulses pile-up in spectroscopic analysis can cause significant errors. Therefore, inhibition of these pulses is a vital step. A way to reduce en-ors due to the pulse pile-up is a pile-up inspection circuitry (PUR). Such a circuit rejects some of the pulse pile-up. Therefore, this circuit leads to counting losses. Determination of these counting losses is an important problem. In this work, a new method is suggested for the determination of the pulse pile-up reject. | en_US |
dc.description.sponsorship | Turkish Phys Soc | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Amer Inst Physics | en_US |
dc.relation.ispartof | Proceedings of The Turkish Physical Society 32nd International Physics Congress (Tps32) | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | [No Keywords] | en_US |
dc.title | The Determination of the Pulse Pile-up Reject (PUR) Counting for X and Gamma Ray Spectrometry | en_US |
dc.type | conferenceObject | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.description.wospublicationid | WOS:000435205100064 | en_US |
dc.description.scopuspublicationid | 2-s2.0-85015990102 | en_US |
dc.department | Gümüşhane Üniversitesi | en_US |
dc.authorid | KARABIDAK, Salih Mustafa / 0000-0002-3096-2476 | |
dc.authorid | KAYA, SELIM / 0000-0001-7477-3522 | |
dc.identifier.volume | 1815 | en_US |
dc.identifier.doi | 10.1063/1.4976408 | |
dc.authorwosid | KARABIDAK, Salih Mustafa / K-4000-2019 | |
dc.authorwosid | KAYA, SELIM / Z-5784-2019 | |
dc.authorscopusid | 18634364300 | |
dc.authorscopusid | 18634155200 | |