Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDuran, Celal
dc.contributor.authorOzdes, Duygu
dc.contributor.authorSahin, Deniz
dc.contributor.authorBulut, Volkan Numan
dc.contributor.authorGundogdu, Ali
dc.contributor.authorSoylak, Mustafa
dc.date.accessioned2019-12-10T06:48:05Z
dc.date.available2019-12-10T06:48:05Z
dc.date.issued2011
dc.identifier.citationC. Duran, D. Ozdes, D. Sahin, V. N. Bulut, A. Gundogdu, M. Soylak, “Preconcentration of Cd(II) and Cu(II) ions by coprecipitation without any carrier element in some food and water samples”, Microchemical Journal, 98, 317–322 (2011).en_US
dc.identifier.issn0026-265X
dc.identifier.urihttps://doi.org/10.1016/j.microc.2011.02.018
dc.description.abstractA simple, rapid, sensitive and environmentally friendly separation and preconcentration procedure, based on the carrier element free coprecipitation (CEFC) of Cu(II) and Cd(II) ions by using an organic coprecipitant, 2-{[4-(4-fluorophenyl)-5-sulphanyl-4H-1,2,4-triazol-3-yl]methyl}-4-{[(4-fluorophenyl) methylene]amino}-5-(4-methylphenyl)-2,4-dihydro-3H-1,2,4-triazol-3-one (MEFMAT) was developed. The analyte ions were determined by flame atomic absorption spectrometric (FAAS) determinations. The optimum conditions for the coprecipitation process were investigated on several commonly tested experimental parameters such as pH of the solution, amount of MEFMAT, sample volume, standing time, centrifugation rate and time. The influences of some anions. cations and transition metals on the recoveries of analyte ions were also investigated, and no considerable interference was observed. The preconcentration factor was found to be 50. The detection limits for Cu(II) and Cd(II) ions based on the three times the standard deviation of the blanks (N:10) were found to be 1.49 and 0.45 mu g L(-1), respectively. The relative standard deviations were found to be lower than 3.5% for both analyte ions. The method was validated by analyzing two certified reference materials (CRM-TMDW-500 Drinking Water and CRM-SA-C Sandy Soil C) and spike tests. The procedure was successfully applied to sea water and stream water as liquid samples and tobacco, hazelnut and black tea as solid samples. (C) 0 2011 Elsevier B.V. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherElsevier Science Bven_US
dc.relation.ispartofMicrochemical Journalen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject[No Keywords]en_US
dc.titlePreconcentration of Cd(II) and Cu(II) ions by coprecipitation without any carrier element in some food and water samplesen_US
dc.typearticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.description.wospublicationidWOS:000290749600024en_US
dc.description.scopuspublicationid2-s2.0-79954437043en_US
dc.departmentGümüşhane Üniversitesien_US
dc.authoridSoylak, Mustafa / 0000-0002-1017-0244
dc.authoridduran, celal / 0000-0002-1306-9061
dc.authoridOZDES, Duygu / 0000-0002-8692-2676
dc.authoridGundogdu, Ali / 0000-0002-9594-4121
dc.identifier.volume98en_US
dc.identifier.issue2en_US
dc.identifier.startpage317en_US
dc.identifier.doi10.1016/j.microc.2011.02.018
dc.identifier.endpage322en_US
dc.authorwosidBulut, Volkan Numan / AAT-5433-2020
dc.authorwosidGUNDOGDU, Ali / AAT-3635-2020
dc.authorwosidSoylak, Mustafa / K-7956-2012
dc.authorwosidOzdes, Duygu / AAK-9819-2021
dc.authorwosidduran, celal / AAK-9834-2021
dc.authorscopusid16042074800
dc.authorscopusid25646623400
dc.authorscopusid36819647500
dc.authorscopusid16041213800
dc.authorscopusid16042269000
dc.authorscopusid7006488616


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster