Ara
Toplam kayıt 54, listelenen: 21-30
Effective atomic numbers and electron densities of CuGaSe2 semiconductor in the energy range 6-511 keV
(JOHN WILEY & SONS LTD, THE ATRIUM, SOUTHERN GATE, CHICHESTER PO19 8SQ, W SUSSEX, ENGLAND, 2008-09)
The effective atomic numbers and electron densities of the CuGaSe2 semiconductor were calculated at 29 different energies from 6.9 to 511.0 keV by using the measured mass attenuation coefficients. Also, the mass attenuation ...
The in situ natural radionuclide (238U,232Th and40K) concentrations in Gümüşhane granitoids: implications for radiological hazard levels of Gümüşhane city, northeast Turkey
(Elsevier, 2019-05-12)
We have carried out 48 in situ measurements on radioactivities of 238U, 232Th and 40K isotopes at the Gümüşhane granitoid plutons employing gamma-ray spectrometer with a NaI(Tl) scintillation detector. The radionuclide ...
Irreversibility Line and Flux Relaxation Bi:2223/Ag tape Prepared by CTFF Technique : H // c axis
(SPRINGER, 233 SPRING ST, NEW YORK, NY 10013 USA, 2010-04-29)
We have studied flux dynamics in Bi:2223/Ag tape prepared by the CTFF technique in the orientation of H//c axis. Irreversibility line (IL) of a Bi:2223/Ag tape has been determined from AC susceptibility and the DC magnetization ...
Hatila Vadisi Milli Parkı Artvin Karayosunlarında Element Analizi
(International Black Sea Environmental Symposium GİRESUN , 2008, 2008-08-25)
[Abstract Not Available]
K L Vacancy Transfer Probabilities For Some Pure Metals In The Atomic Range 24 Z 56 Usıng 59 5 Kev Photons
(Batman Üniversitesi Batman University Yasam Bilimleri Dergisi; Cilt 4 Sayı 1, 2014)
K-L tabakası için boşluk geçiş olasılığı (ηKL) Cr, Fe, Co, Cu, Zn, Ga, Se, Y, Mo, Cd, In,
Sn, Te ve Ba gibi bazı saf metaller için IKβ/IKα şiddet oranı ölçümlerinden elde edildi. Hedef
metaller 59,5 keV’lik gama ışınları ...
Measurment of L Subshell X-Ray Production Cross-Sections at Energy 31,635 keV and L Subshell Fluoressance Yields for Elements 74 ? Z ? 92
(X-Ray Spectrometry, 2002)
TheL
l
,L
α
,L
β
andL
γ
X-rayproductioncross-sectionsandL
i
(
i
=
1,2and3)X-rayfluorescence(XRF)cross-sectionshavebeenmeasuredforsomeelementsintheatomicrange55
≤
Z
≤
81at59.54keV.ThevaluesofL
i
...
Measurment of L X-Ray Production Cross-Sections and Li Subshell Florescence Yields
(Journal of Electron Spectrometry And Related Phenomena, 2003-04-03)
Li (i=1, 2 and 3) X-ray production cross sections have been measured for 14 elements in the atomic number range 55≤Z≤81 at 15.73 keV. The values of Li subshell fluorescence yields (ω1, ω2 and ω3) have been determined using ...
A New Method to Compensate for Counting Losses due to System Dead Time
(Nuclear Instruments and Methods in Physics Research A, 2009-05-21)
Determination of count losses and pile-up pulse effects in quantitative and qualitative analysis became a vital step in various analyses. Therefore, compensating for counting losses is of importance. These counting losses ...
Some criteria at DTL design for Turkish Accelerator Center (TAC) linac
(Azerbaijan Journal of Physics, 2010-06)
Linear acceleretors (linacs) are mostly used as first step of acceleration process in the present. Turkish Accelerator Center (TAC) linac of which technical design report will have been completed in 2011 has been designed ...
Yeni Üniversite Sınav Sisteminin Liselerde Fizik Öğretimine Etkileri
(Çukurova Üniversitesi Eğitim Fakültesi Dergisi, 2002)
It has been continuously discussed that changing the system of university selection examination from two phases to one phase has negatively affected the teaching and learning at the high schools. This study has planned to ...